Neuroflow
Study mode
Slide 11

Original lecture slide

100%
Original lecture slide 11 showing MRI and CT fusion from image space to stereotactic space

STEREOTACTIC PLANNING

  • MRI + CT fusion: from image space to stereotactic space
  • 1 MRI — High-resolution anatomy
  • 2 AC–PC — Define reference frame
  • 3 CT — Stereotactic coordinates
  • 4 FUSION — Rigid registration
  • 5 TARGET — Nucleus / pathway
  • 6 TRAJECTORY — Safe entry → target
  • REGISTRATION ERROR = TARGETING ERROR
  • Always inspect fusion quality before trusting a coordinate.
  • Targeting principles: contemporary DBS stereotactic imaging and surgical planning literature.
  • Dr Vikas Kathuria | MCh Neurosurgery

Image placeholder

11A HIGH-RESOLUTION MRI — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeClinical MRI
DescriptionHigh-resolution planning MRI.
Clinical purposeDemonstrate anatomical image space.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11

Image placeholder

11B STEREOTACTIC CT — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeCT
DescriptionStereotactic CT with reference system.
Clinical purposeDemonstrate stereotactic space.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11

Image placeholder

11C MRI + CT FUSION — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeMRI-CT fusion
DescriptionMRI and CT fusion in multiple planes.
Clinical purposeInspect registration quality.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11

Image placeholder

11D REGISTRATION LANDMARKS — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeMRI-CT fusion
DescriptionLandmarks used to inspect registration.
Clinical purposeTeach visual quality control.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11

Image placeholder

11E TARGET + TRAJECTORY — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeMRI-CT fusion
DescriptionTarget and trajectory planning screenshot.
Clinical purposeConnect registration to the surgical plan.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11

Image placeholder

11F MISREGISTRATION — INSERT AUTHENTIC IMAGE

Real clinical image required

Image typeMRI-CT fusion
DescriptionAuthentic example of registration error.
Clinical purposeShow error transfer into targeting.
Suggested sourceINSERT AUTHENTIC CLINICAL / PUBLISHED IMAGE HERE
Copyright statusSource and publication rights must be confirmed before use.
CaptionTo be written with the final image
AssociationModule 03 · Slide 11